Echuan Hydraulic
Echuan Hydraulic Machinery Co., Ltd.
No. 53 Shuikou Avenue, Huizhou, Guangdong, China
Tel +86-752-2399772 · WhatsApp +86-13422935851
[email protected] · www.echuan-hydraulic.com
Product Data Sheet

Global one-stop procurement platform for hydraulic spare parts.

Product Description

Dold BD9080.12/61

The Dold BD9080.12/61 is a versatile multifunction measuring relay from the VARIMETER PRO series, designed for comprehensive monitoring of 3-phase AC mains. It reliably detects and signals various network faults, including overvoltage, undervoltage, incorrect phase sequence, phase failure (even with regenerated voltage), and asymmetry. Featuring an LCD display for easy visualization of measured values and parameters, the BD9080.12/61 offers adjustable thresholds and time delays to prevent nuisance tripping. This model, with its specific /61 variant features (requiring an AC 230V auxiliary supply), is suitable for demanding industrial applications requiring precise and dependable mains protection to safeguard equipment and ensure operational continuity.

Technical Specifications:

  • Type: Multifunction Measuring Relay
  • Model: BD9080.12/61
  • Monitored System: 3-phase AC mains (3P+N or 3P selectable)
  • Nominal Voltage (Monitored Un): 3 AC 400 / 230 V (L-L / L-N)
  • Auxiliary Supply Voltage (Us): AC 230 V, 50/60 Hz
  • Frequency Range: 45 … 65 Hz
  • Monitoring Functions:
    • Overvoltage (Umax): Adjustable 1.0 … 1.3 Un
    • Undervoltage (Umin): Adjustable 0.7 … 1.0 Un
    • Phase Sequence
    • Phase Failure (detection with regenerated voltage > 60% Un)
    • Asymmetry: Adjustable 5 … 25 %
  • Measuring Principle: True RMS
  • Display: LCD for measured values, parameters, and fault indication
  • Output Contacts: 2 changeover contacts (2 CO)
  • Contact Switching Capacity (AC1): 5 A / 250 VAC
  • Contact Switching Capacity (DC1): 5 A / 24 VDC
  • Time Delays:
    • Start-up delay (tv): Adjustable 0 … 60 s
    • Tripping delay (ta) for Umin, Umax, Asymmetry: Adjustable 0.1 … 60 s
    • Tripping delay for phase sequence/failure: < 200 ms
  • Operating Temperature: -25 °C to +60 °C
  • Storage Temperature: -40 °C to +70 °C
  • Degree of Protection (Housing / Terminals): IP40 / IP20
  • Mounting: DIN rail (35 mm) according to EN 60715
  • Overall Width: 35 mm
  • Standards: IEC/EN 60255-1, IEC/EN 60947-5-1

Dold BD9080.12/61 - Image 1

Dold BD9080.12/61 - Image 2

Dold BD9080.12/61 - Image 3

Dold BD9080.12/61 - Image 4

Dold BD9080.12/61 - Image 5

Dold BD9080.12/61 - Image 6

Dold BD9080.12/61 - Image 7

Dold BD9080.12/61

Model:Dold BD9080.12/61

BrandDOLD
ModelBD9080.12/61
Part No.Dold BD9080.12/61
CategoryElectrical
Linkhttps://www.echuan-hydraulic.com/product/dold-bd9080-12-61
Request a quote: [email protected] · WhatsApp +86-13422935851 · Tel +86-752-2399772
All brand names and model numbers are the property of their respective manufacturers and are used for identification only. Pictures are for reference; confirm specifications before ordering.